Arctic Shield Insulation Values Specs for Post Frame Construction

Arctic Shield Insulation Values

Specs for Post Frame Construction

Roof

The thermal values for roof applications in post frame construction were derived by testing an assembly consisting of a corrugated metal exterior, 2" x 4" purlins, Arctic Shield Insulation, a 2" x 6" to represent the top cord of a truss, and 1/2" wafer board. The thermal values are for both exposed insulation and applications where the insulation is covered for fire codes. 

Thermal Values

Heat Flow Up Heat Flow Down U Value Up U Value Down K Value Up K Value Down

Arctic Shield w/Wafer Board

6.93 15.11 .144 .066 .144 .066

Arctic Shield w/Metal Interior

6.22 14.40 .161 .069 .161 .069

Arctic Shield Exposed to Interior

4.91* 12.81* .204* .078* .204* .078*

 All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.

Walls

The thermal values for Arctic Shield installed in the walls of post frame buildings are based on testing of an assembly consisting of corrugated metal exterior, 2" x 4" girts, Arctic Shield Insulation, a 4" x 6" to represent the support beam, and 1/2" wafer board as an interior wall covering.

 

Thermal Values

Heat Flow Horz. U Value Horz. K Value Horz.

Arctic Shield w/Wafer Board

6.93 .144 .144

Arctic Shield w/Metal Interior

6.22 .161 .161

Arctic Shield Exposed to Interior

4.91* .204 .204*

 All Thermal Values are corrected for frame loss.
* Includes thermal resistance of 1.70 for interior air film.